Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5CSE

Streptavidin-S112Y-K121E Complexed with Palladium-Containing Biotin Ligand

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06DA
Synchrotron siteSLS
BeamlineX06DA
Temperature [K]100
Detector technologyPIXEL
Collection date2015-02-17
DetectorPSI PILATUS 6M
Wavelength(s)1.0
Spacegroup nameC 2 2 21
Unit cell lengths81.368, 81.460, 90.811
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.622 - 1.792
R-factor0.2247
Rwork0.223
R-free0.25580
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1luq
RMSD bond length0.007
RMSD bond angle1.110
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.6221.856
High resolution limit [Å]1.7921.792
Rmerge0.0900.735
Number of reflections53292
<I/σ(I)>18.183.2
Completeness [%]97.689.28
Redundancy11.89.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29315-25% PEG 1500, 100mM SPG buffer (mixed succinic acid, sodium dihydrogen phosphate and glycine in the ratio 2:7:7; 75% at pH 4 and 25% at pH 10)

222415

PDB entries from 2024-07-10