5CN0
Artificial HIV fusion inhibitor AP2 fused to the C-terminus of gp41 NHR
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2013-04-08 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.5418 |
Spacegroup name | H 3 2 |
Unit cell lengths | 36.187, 36.187, 286.003 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 31.778 - 1.901 |
R-factor | 0.1999 |
Rwork | 0.196 |
R-free | 0.23240 |
RMSD bond length | 0.019 |
RMSD bond angle | 1.561 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.8.2_1309) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 31.780 |
High resolution limit [Å] | 1.900 |
Number of reflections | 64372 |
<I/σ(I)> | 28.9 |
Completeness [%] | 100.0 |
Redundancy | 10.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 289 | 0.1M Tris-HCl pH 8.0, 34% (w/v) PEG 3350, 0.2M MgCl2 |