Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5CKQ

CUB1-EGF-CUB2 domains of rat MASP-1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2013-05-13
DetectorDECTRIS PILATUS 2M
Wavelength(s)0.9795
Spacegroup nameI 2 3
Unit cell lengths152.710, 152.710, 152.710
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution76.355 - 3.704
R-factor0.25
Rwork0.247
R-free0.29370
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3dem
RMSD bond length0.002
RMSD bond angle0.751
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]76.4004.140
High resolution limit [Å]3.7003.700
Rmerge0.742
Number of reflections6473
<I/σ(I)>9.22.1
Completeness [%]99.999.9
Redundancy5.65.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.5293100 mM imidazole/MOPS pH 6.5 containing 20% ethylene glycol and 10% PEG8K

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon