5CKA
Human beta-2 microglobulin double mutant W60G-N83V
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID29 |
Synchrotron site | ESRF |
Beamline | ID29 |
Temperature [K] | 110 |
Detector technology | PIXEL |
Collection date | 2014-03-02 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.99 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 76.980, 28.910, 57.320 |
Unit cell angles | 90.00, 128.57, 90.00 |
Refinement procedure
Resolution | 25.750 - 1.700 |
R-factor | 0.1813 |
Rwork | 0.176 |
R-free | 0.22630 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2z9t |
RMSD bond length | 0.010 |
RMSD bond angle | 1.380 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | MOLREP |
Refinement software | PHENIX (1.8.4_1496) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 25.750 | 1.790 |
High resolution limit [Å] | 1.700 | 1.700 |
Rmerge | 0.050 | 0.200 |
Number of reflections | 10677 | |
<I/σ(I)> | 12.4 | 5 |
Completeness [%] | 96.7 | 97.1 |
Redundancy | 3.5 | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 293 | 0.1 M MES, 21% w/v PEG 4000, 15% glycerol, 0.2 M ammonium acetate |