5CG8

NgTET1 in complex with 5hmC DNA

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-BM
Synchrotron siteAPS
Beamline22-BM
Temperature [K]100
Detector technologyCCD
Collection date2014-03-09
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)1.0000
Spacegroup nameI 21 21 21
Unit cell lengths83.802, 107.360, 167.671
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution27.554 - 2.702
R-factor0.1928
Rwork0.191
R-free0.22950
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4lt5
RMSD bond length0.006
RMSD bond angle0.892
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]27.6002.790
High resolution limit [Å]2.6902.690
Rmerge0.0660.977
Number of reflections20985
<I/σ(I)>29.22.9
Completeness [%]99.7100
Redundancy9.910
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.528925% (w/v) polyethylene glycol monomethyl ether 550, 10 mM ZnSO4, and 100 mM MES, pH 6.5

221716