5CFH

human beta-2 microglobulin double mutant W60G-Y63W

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]110
Detector technologyPIXEL
Collection date2014-03-02
DetectorPSI PILATUS 6M
Wavelength(s)0.99
Spacegroup nameC 1 2 1
Unit cell lengths93.346, 29.090, 44.410
Unit cell angles90.00, 113.01, 90.00
Refinement procedure
Resolution25.110 - 1.490
R-factor0.17198
Rwork0.169
R-free0.22961
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2z9t
RMSD bond length0.016
RMSD bond angle1.752
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0049)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.1101.570
High resolution limit [Å]1.4901.490
Rmerge0.0750.220
Number of reflections17435
<I/σ(I)>9.64.5
Completeness [%]95.896.5
Redundancy3.33.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.5293PEG 10000, HEPES

222415