5C16
Myotubularin-related proetin 1
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 5C (4A) |
| Synchrotron site | PAL/PLS |
| Beamline | 5C (4A) |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-11-07 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.9796 |
| Spacegroup name | P 1 |
| Unit cell lengths | 67.219, 96.587, 97.581 |
| Unit cell angles | 87.60, 86.07, 77.33 |
Refinement procedure
| Resolution | 34.814 - 2.070 |
| R-factor | 0.2229 |
| Rwork | 0.220 |
| R-free | 0.27350 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.040 |
| Data scaling software | HKL-2000 |
| Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.110 |
| High resolution limit [Å] | 2.000 | 2.070 |
| Rmerge | 0.255 | |
| Number of reflections | 136495 | |
| <I/σ(I)> | 18.9 | 3.2 |
| Completeness [%] | 86.1 | 84 |
| Redundancy | 2.5 | 2.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 277 | Sodium-HEPES, PEG 20000 |