Ticagrelor antidote candidate MEDI2452 in complex with ticagrelor

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2014-06-13
DetectorDECTRIS PILATUS
Spacegroup nameP 21 21 2
Unit cell lengths69.310, 173.490, 42.580
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution41.000 - 2.160
R-factor0.2162
Rwork0.214
R-free0.25920
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1aqk
RMSD bond length0.010
RMSD bond angle1.250
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareBUSTER (2.11.6)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.4002.050
High resolution limit [Å]1.9801.980
Rmerge0.1001.310
Number of reflections36570
<I/σ(I)>10.71.1
Completeness [%]99.494.9
Redundancy6.46.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

222926

PDB entries from 2024-07-24