5AFK

alpha7-AChBP in complex with lobeline and fragment 2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]100
Detector technologyCCD
Collection date2013-04-02
DetectorADSC CCD
Spacegroup nameP 21 21 21
Unit cell lengths85.695, 112.293, 144.305
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution36.841 - 2.381
R-factor0.1701
Rwork0.167
R-free0.23000
Structure solution methodOTHER
Starting model (for MR)NONE
RMSD bond length0.008
RMSD bond angle1.200
Refinement softwarePHENIX ((PHENIX.REFINE))
Data quality characteristics
 Overall
Low resolution limit [Å]48.230
High resolution limit [Å]2.381
Rmerge0.070
Number of reflections55979
<I/σ(I)>17
Completeness [%]99.7
Redundancy5.9