Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5WDQ

H-Ras mutant L120A bound to GMP-PNP at 100K

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.1
Synchrotron siteALS
Beamline8.2.1
Temperature [K]100
Detector technologyCCD
Collection date2016-07-14
DetectorADSC QUANTUM 315r
Wavelength(s)1.0
Spacegroup nameH 3 2
Unit cell lengths87.960, 87.960, 133.105
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution44.368 - 1.250
R-factor0.1407
Rwork0.140
R-free0.15000
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)3k8y
RMSD bond length0.009
RMSD bond angle1.089
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.11.1_2575: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.3701.270
High resolution limit [Å]1.2501.250
Rmerge0.0450.594
Rpim0.0100.308
Number of reflections542742444
<I/σ(I)>36.92.4
Completeness [%]99.092
Redundancy18.74.6
CC(1/2)1.0000.790
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29317% PEG8000, 200 mM calcium acetate, 100 mM MES/NaOH, pH 6.0

219869

PDB entries from 2024-05-15