Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5VFC

WDR5 bound to inhibitor MM-589

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-F
Synchrotron siteAPS
Beamline21-ID-F
Temperature [K]100
Detector technologyCCD
Collection date2016-11-29
DetectorRAYONIX MX300-HS
Wavelength(s)0.9787
Spacegroup nameC 1 2 1
Unit cell lengths88.348, 58.559, 56.801
Unit cell angles90.00, 96.16, 90.00
Refinement procedure
Resolution15.550 - 1.640
R-factor0.149
Rwork0.148
R-free0.17400
RMSD bond length0.010
RMSD bond angle1.140
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwareBUSTER (2.10.2)
Data quality characteristics
 Overall
Low resolution limit [Å]15.550
High resolution limit [Å]1.640
Rmerge0.063
Number of reflections35269
<I/σ(I)>10
Completeness [%]99.9
Redundancy6.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.1 M Na Bis-Tris pH 6.5, 26% PEG 8000 and 0.1 M ammonium sulfate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon