Grb7 SH2 with bicyclic peptide containing pY mimetic

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2016-10-14
DetectorADSC QUANTUM 315r
Wavelength(s)0.9537
Spacegroup nameP 1 21 1
Unit cell lengths45.070, 107.610, 48.012
Unit cell angles90.00, 101.38, 90.00
Refinement procedure
Resolution44.184 - 2.150
R-factor0.2087
Rwork0.207
R-free0.24590
RMSD bond length0.009
RMSD bond angle1.256
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 Overall
Low resolution limit [Å]44.184
High resolution limit [Å]2.150
Number of reflections24095
<I/σ(I)>4.9
Completeness [%]98.7
Redundancy2.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP293PEG3350, NaSCN

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon