5TO1
HtrA2 exposed (L266R, F303A) mutant
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID29 |
Synchrotron site | ESRF |
Beamline | ID29 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-12-13 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.000 |
Spacegroup name | H 3 |
Unit cell lengths | 84.180, 84.180, 126.772 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 47.800 - 1.690 |
R-factor | 0.1695 |
Rwork | 0.168 |
R-free | 0.19750 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1lcy |
RMSD bond length | 0.009 |
RMSD bond angle | 0.960 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.800 | 1.750 |
High resolution limit [Å] | 1.690 | 1.690 |
Rmerge | 0.070 | 0.882 |
Number of reflections | 37468 | |
<I/σ(I)> | 12.4 | 1.7 |
Completeness [%] | 99.9 | 99.9 |
Redundancy | 6.6 | 6.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 293 | 0.1 M MES pH 6.0, 1 M LiCl, and 15-20% (w/v) PEG-6000 |