5O7I
ERK5 in complex with a pyrrole inhibitor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I02 |
Synchrotron site | Diamond |
Beamline | I02 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2005-02-05 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.378520 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 93.910, 93.910, 113.748 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.650 - 2.380 |
R-factor | 0.1824 |
Rwork | 0.180 |
R-free | 0.22030 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5byz |
RMSD bond length | 0.010 |
RMSD bond angle | 1.040 |
Data reduction software | XDS |
Data scaling software | Aimless (0.5.17) |
Phasing software | MOLREP (11.4.04) |
Refinement software | BUSTER (2.10.2) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.650 | 2.500 |
High resolution limit [Å] | 2.380 | 2.380 |
Rmerge | 0.150 | 1.290 |
Number of reflections | 21010 | 2719 |
<I/σ(I)> | 12.5 | 2.2 |
Completeness [%] | 99.9 | 99.56 |
Redundancy | 14.2 | 15 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 293 | 5 % (v/v) PEG 6000, 0.1 M MES (pH 6.0), 5 mM DTT |