5NWH
Potent inhibitors of NUDT5 silence hormone signaling in breast cancer
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-12-09 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.92 |
Spacegroup name | I 1 2 1 |
Unit cell lengths | 100.561, 40.146, 104.064 |
Unit cell angles | 90.00, 113.38, 90.00 |
Refinement procedure
Resolution | 46.153 - 2.600 |
R-factor | 0.1906 |
Rwork | 0.187 |
R-free | 0.25280 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3ac9 |
RMSD bond length | 0.007 |
RMSD bond angle | 1.308 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX (dev_1631) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 46.200 |
High resolution limit [Å] | 2.600 |
Number of reflections | 11883 |
<I/σ(I)> | 15.6 |
Completeness [%] | 98.0 |
Redundancy | 3.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 291.15 | 26 mg/ml in 0.1 M HEPES, pH 7.5, 300 mM NaCl, 10% Glycerol, and 1 mM TCEP |