5N49
BRPF2 in complex with Compound 7
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-07-12 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.918409 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 56.556, 56.983, 102.340 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 38.070 - 1.940 |
R-factor | 0.1834 |
Rwork | 0.181 |
R-free | 0.22911 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.024 |
RMSD bond angle | 2.134 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0135) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.070 | 2.030 |
High resolution limit [Å] | 1.940 | 1.940 |
Rmerge | 0.057 | 0.504 |
Number of reflections | 34549 | |
<I/σ(I)> | 13 | 2.6 |
Completeness [%] | 99.6 | 99.6 |
Redundancy | 3.6 | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 295 | 100 mM bis-tris pH 6.5, 30% (w/v) PEG 3350 |