5M5F
Thermolysin in complex with inhibitor and krypton
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ELETTRA BEAMLINE 5.2R |
| Synchrotron site | ELETTRA |
| Beamline | 5.2R |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2015-10-05 |
| Detector | DECTRIS PILATUS 2M |
| Wavelength(s) | 0.859400 |
| Spacegroup name | P 61 2 2 |
| Unit cell lengths | 92.428, 92.428, 130.192 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 43.552 - 1.330 |
| R-factor | 0.1127 |
| Rwork | 0.111 |
| R-free | 0.13870 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 8tln |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.169 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.410 |
| High resolution limit [Å] | 1.330 | 1.330 |
| Rmerge | 0.499 | |
| Number of reflections | 75575 | |
| <I/σ(I)> | 25.98 | 6.26 |
| Completeness [%] | 100.0 | 99.7 |
| Redundancy | 20.7 | 19.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 291.15 | 50 MM TRIS/HCL, 1.9 M CSCL, 50% DMSO |