5KY4
mouse POFUT1 in complex with mouse Notch1 EGF26 and GDP
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | CLSI BEAMLINE 08ID-1 |
| Synchrotron site | CLSI |
| Beamline | 08ID-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2012-04-01 |
| Detector | RAYONIX MX-300 |
| Wavelength(s) | 0.97949 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 51.920, 66.372, 110.910 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 47.023 - 1.472 |
| R-factor | 0.154 |
| Rwork | 0.153 |
| R-free | 0.16750 |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.014 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.530 |
| High resolution limit [Å] | 1.470 | 1.470 |
| Rmerge | 0.134 | 1.218 |
| Number of reflections | 65598 | |
| <I/σ(I)> | 7.6 | 1.3 |
| Completeness [%] | 100.0 | 99 |
| Redundancy | 7.2 | 6.8 |
| CC(1/2) | 0.991 | 0.537 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 295 | 20% PEG2000 MME, 50 mM Tris pH 8.5 |