5IRC
p190A GAP domain complex with RhoA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 77 |
Detector technology | CCD |
Collection date | 2012-12-01 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 1.0 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 47.026, 112.322, 147.611 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 32.538 - 1.720 |
R-factor | 0.1712 |
Rwork | 0.170 |
R-free | 0.21260 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.152 |
Data scaling software | SCALEPACK |
Phasing software | BALBES |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 35.000 | 35.000 | 1.750 |
High resolution limit [Å] | 1.720 | 4.670 | 1.720 |
Rmerge | 0.059 | 0.049 | 0.367 |
Total number of observations | 459261 | ||
Number of reflections | 81511 | ||
<I/σ(I)> | 12.6 | ||
Completeness [%] | 97.0 | 99.9 | 70 |
Redundancy | 5.6 | 5.9 | 2.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 6.5 | 294 | 30% PEG 2000MME 150mM KCSN 100mM MES, pH 6.5 |