5GTR
estrogen receptor alpha in complex with a stabilized peptide antagonist 6
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2015-11-10 |
| Detector | DECTRIS PILATUS 300K |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 2 21 21 |
| Unit cell lengths | 54.787, 60.219, 66.457 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.438 - 2.804 |
| R-factor | 0.2281 |
| Rwork | 0.221 |
| R-free | 0.36740 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.328 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-3000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 20.000 |
| High resolution limit [Å] | 2.800 |
| Number of reflections | 5526 |
| <I/σ(I)> | 13 |
| Completeness [%] | 95.5 |
| Redundancy | 4.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 293 | 0.2 M Magnesium acetate tetrahydrate, 0.1 M Sodium cacodylate trihydrate, 20% w/v Polyethylene glycol 8000 |