5GOM
Truncated mitofusin-1, transition-like state
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-11-15 |
Detector | RAYONIX MX-225 |
Wavelength(s) | 0.91800 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 146.108, 45.982, 146.180 |
Unit cell angles | 90.00, 92.23, 90.00 |
Refinement procedure
Resolution | 48.690 - 2.802 |
R-factor | 0.1926 |
Rwork | 0.189 |
R-free | 0.25900 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 0.948 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 48.697 |
High resolution limit [Å] | 2.802 |
Number of reflections | 181542 |
<I/σ(I)> | 20.55 |
Completeness [%] | 99.1 |
Redundancy | 7.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100mM MES (pH 6.0), 240mM NaCl, 36% pentaerythriol propoxylate (5/4 PO/OH) |