Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5FNK

Native state mass spectrometry, surface plasmon resonance and X-ray crystallography correlate strongly as a fragment screening combination

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX1
Synchrotron siteAustralian Synchrotron
BeamlineMX1
Temperature [K]100
Detector technologyCCD
Collection date2015-06-02
DetectorADSC CCD
Spacegroup nameP 1 21 1
Unit cell lengths42.350, 41.516, 72.157
Unit cell angles90.00, 104.42, 90.00
Refinement procedure
Resolution69.880 - 1.590
R-factor0.14909
Rwork0.147
R-free0.19522
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4cq0
RMSD bond length0.020
RMSD bond angle1.971
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0131)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]41.5001.610
High resolution limit [Å]1.5901.590
Rmerge0.0800.600
Number of reflections33070
<I/σ(I)>16.82.9
Completeness [%]99.590.7
Redundancy7.36.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.515 MG/ML PROTEIN WITH 2.7 M AMMONIUM SULFATE, 100 MM TRIS PH 8.5 AT 8 C IN SITTING DROPS.

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon