5FBW
PI4KB in complex with Rab11 and the MI369 Inhibitor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-05-29 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9796 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 49.066, 104.091, 187.559 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.469 - 3.487 |
R-factor | 0.248 |
Rwork | 0.246 |
R-free | 0.28310 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4d0l |
RMSD bond length | 0.005 |
RMSD bond angle | 1.147 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.470 | 3.610 |
High resolution limit [Å] | 3.480 | 3.480 |
Rmerge | 0.191 | |
Total number of observations | 54212 | |
Number of reflections | 12696 | |
<I/σ(I)> | 6.77 | 0.87 |
Completeness [%] | 98.3 | |
Redundancy | 4.27 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291 | 0.2M ammonium sulfate, 0.1M MES pH=6.5, 20% (w/v) PEG 8000 |