5AGW

Bcl-2 alpha beta-1 complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2015-12-12
DetectorADSC CCD
Spacegroup nameP 43 21 2
Unit cell lengths87.673, 87.673, 107.480
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution33.969 - 2.695
R-factor0.2051
Rwork0.202
R-free0.27190
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)UNPUBLISHED BCL-2 BECLIN BH3 COMPLEX
RMSD bond length0.009
RMSD bond angle1.274
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX ((PHENIX.REFINE))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]33.9702.790
High resolution limit [Å]2.7002.700
Rmerge0.100
Number of reflections12081
<I/σ(I)>18.291.08
Completeness [%]99.898.3
Redundancy13.49.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
170.02M CACL2, 0.1M MOPS PH7.0, 10% 2-PROPANOL

219869