4ZRQ
E88 deletion mutant of CD320 in complex with TC2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2014-07-16 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 1 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 98.404, 98.404, 356.341 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.434 - 2.600 |
R-factor | 0.2001 |
Rwork | 0.199 |
R-free | 0.23050 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.886 |
Data reduction software | XDS |
Data scaling software | Aimless |
Refinement software | PHENIX |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 29.434 | |
High resolution limit [Å] | 2.600 | 2.600 |
Rmerge | 1.620 | |
Number of reflections | 54979 | |
<I/σ(I)> | 16.8 | 2.2 |
Completeness [%] | 99.9 | 100 |
Redundancy | 10.8 | 11.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293.15 | PEG3350, L-Proline, Hepes |