4ZHI
Eg5 motor domain mutant E162S
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | BRUKER AXS MICROSTAR |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2008-04-10 |
| Detector | Bruker Platinum 135 |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 52.720, 81.220, 82.600 |
| Unit cell angles | 90.00, 94.31, 90.00 |
Refinement procedure
| Resolution | 25.000 - 2.300 |
| Rwork | 0.254 |
| R-free | 0.30350 |
| Data reduction software | SAINT |
| Data scaling software | PROTEUM PLUS |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 25.000 | 2.400 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Rmerge | 0.067 | 0.256 |
| Number of reflections | 30404 | |
| <I/σ(I)> | 8.45 | 2.77 |
| Completeness [%] | 98.1 | 96.6 |
| Redundancy | 1.85 | 1.45 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 277 | 200 mM NaF and 18-20% PEG 3350 |