Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4Z90

ELIC bound with the anesthetic isoflurane in the resting state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL12-2
Synchrotron siteSSRL
BeamlineBL12-2
Temperature [K]100
Detector technologyPIXEL
Collection date2014-07-04
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9795
Spacegroup nameP 1 21 1
Unit cell lengths105.848, 267.079, 111.128
Unit cell angles90.00, 106.94, 90.00
Refinement procedure
Resolution36.973 - 3.000
R-factor0.2107
Rwork0.209
R-free0.24320
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3rqu
RMSD bond length0.014
RMSD bond angle1.328
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.6303.160
High resolution limit [Å]3.0003.000
Rmerge0.251
Number of reflections117464
<I/σ(I)>14.91.6
Completeness [%]99.9100
Redundancy21.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.1277isoflurane, PEG 4000, ammonium sulfate, MES

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon