Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4Z83

PKAB3 in complex with pyrrolidine inhibitor 47a

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyCCD
Collection date2012-11-24
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.918410
Spacegroup nameP 21 21 21
Unit cell lengths82.575, 61.491, 78.948
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution35.614 - 1.800
R-factor0.1818
Rwork0.180
R-free0.21750
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1rdq
RMSD bond length0.026
RMSD bond angle1.013
Data reduction softwareXDS (November 11, 2013)
Phasing softwarePHASER (2.5.5)
Refinement softwarePHENIX (1.8.4_1496)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.6141.823
High resolution limit [Å]1.8001.800
Rmerge0.086
Number of reflections37443
<I/σ(I)>10.78
Completeness [%]98.60.85
Redundancy3.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7277The droplets, containing 16 mg/ml PKAB3, 25 mM Bis-Tris-HCl, pH 7.0, 150 mM KCl, 1.5mM octanoyl-N-methylglucamide and 0.8 mM PKI peptide, were equilibrated against 12-26 % (v/v) methanol.

222415

PDB entries from 2024-07-10

PDB statisticsPDBj update infoContact PDBjnumon