4Y53
Endothiapepsin in complex with fragment 54
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-11-18 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.891200 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 45.211, 72.620, 52.661 |
Unit cell angles | 90.00, 109.77, 90.00 |
Refinement procedure
Resolution | 27.947 - 1.620 |
R-factor | 0.1861 |
Rwork | 0.185 |
R-free | 0.20630 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3pcw |
RMSD bond length | 0.007 |
RMSD bond angle | 1.081 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.8.4_1492) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.550 | 1.720 |
High resolution limit [Å] | 1.620 | 1.620 |
Rmerge | 0.430 | |
Number of reflections | 40417 | |
<I/σ(I)> | 14.54 | 3.25 |
Completeness [%] | 99.0 | 97.3 |
Redundancy | 4.06 | 3.69 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4.6 | 290 | 0.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000 |