4Y08
ONE MINUTE IRON LOADED HUMAN H FERRITIN
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-07-05 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.920 |
Spacegroup name | F 4 3 2 |
Unit cell lengths | 184.140, 184.140, 184.140 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 27.760 - 1.340 |
R-factor | 0.16304 |
Rwork | 0.162 |
R-free | 0.17347 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3ajo |
RMSD bond length | 0.006 |
RMSD bond angle | 1.037 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0073) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 29.110 | 1.410 |
High resolution limit [Å] | 1.340 | 1.340 |
Rmerge | 0.069 | 0.395 |
Number of reflections | 60022 | |
<I/σ(I)> | 28.2 | 8 |
Completeness [%] | 99.7 | 100 |
Redundancy | 20 | 20 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 9 | 281 | 2.0 M magnesium chloride and 0.1 M BICINE at pH 9.0 |