Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4Y08

ONE MINUTE IRON LOADED HUMAN H FERRITIN

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2013-07-05
DetectorDECTRIS PILATUS 2M
Wavelength(s)0.920
Spacegroup nameF 4 3 2
Unit cell lengths184.140, 184.140, 184.140
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution27.760 - 1.340
R-factor0.16304
Rwork0.162
R-free0.17347
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ajo
RMSD bond length0.006
RMSD bond angle1.037
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]29.1101.410
High resolution limit [Å]1.3401.340
Rmerge0.0690.395
Number of reflections60022
<I/σ(I)>28.28
Completeness [%]99.7100
Redundancy2020
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP92812.0 M magnesium chloride and 0.1 M BICINE at pH 9.0

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon