Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4XT9

RORgamma (263-509) complexed with GSK2435341A and SRC2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U
Synchrotron siteSSRF
BeamlineBL17U
Temperature [K]100
Detector technologyCCD
Collection date2010-10-20
DetectorADSC QUANTUM 210r
Wavelength(s)1.0
Spacegroup nameP 41 21 2
Unit cell lengths62.000, 62.000, 154.700
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution57.580 - 2.250
R-factor0.21569
Rwork0.214
R-free0.24489
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3l0j
RMSD bond length0.007
RMSD bond angle1.008
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareREFMAC (5.5.0102)
Data quality characteristics
 Overall
Low resolution limit [Å]57.580
High resolution limit [Å]2.250
Number of reflections14291
<I/σ(I)>22.2
Completeness [%]99.8
Redundancy7.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2960.2M Ammonium Sulfate, 0.1M Bis-Tris, pH 6.5, 14% (w/v) PEG 8000

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon