4XGY
GFP based antibody (fluorobody)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-10-27 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.97915 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 63.350, 63.350, 125.900 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 31.675 - 1.494 |
R-factor | 0.1461 |
Rwork | 0.145 |
R-free | 0.16650 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2b3p |
RMSD bond length | 0.009 |
RMSD bond angle | 1.335 |
Data reduction software | iMOSFLM |
Data scaling software | iMOSFLM |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 31.680 |
High resolution limit [Å] | 1.494 |
Number of reflections | 42096 |
<I/σ(I)> | 264.06 |
Completeness [%] | 99.3 |
Redundancy | 23.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 291 | 40% PEG400, 0.1M Hepes, pH 7.0 |