Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4XAS

mGluR2 ECD ligand complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 31-ID
Synchrotron siteAPS
Beamline31-ID
Temperature [K]100
Detector technologyCCD
Collection date2014-03-13
DetectorRAYONIX MX-225
Wavelength(s)0.97931
Spacegroup nameP 21 21 2
Unit cell lengths78.044, 135.858, 92.200
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.700 - 2.350
R-factor0.2144
Rwork0.212
R-free0.28010
RMSD bond length0.010
RMSD bond angle1.120
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareBUSTER-TNT (BUSTER 2.11.5)
Data quality characteristics
 Overall
Low resolution limit [Å]19.700
High resolution limit [Å]2.350
Number of reflections40851
<I/σ(I)>8
Completeness [%]98.5
Redundancy6.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION295100mM Sodium Acetate pH 4.6 + 23% PEG 10K

218853

PDB entries from 2024-04-24