Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4XAQ

mGluR2 ECD and mGluR3 ECD with ligands

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 31-ID
Synchrotron siteAPS
Beamline31-ID
Temperature [K]100
Detector technologyCCD
Collection date2010-06-17
DetectorRAYONIX MX-225
Wavelength(s)0.97929
Spacegroup nameP 21 21 2
Unit cell lengths81.644, 159.652, 93.880
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution25.520 - 2.210
R-factor0.1877
Rwork0.186
R-free0.22470
RMSD bond length0.010
RMSD bond angle1.030
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareBUSTER-TNT (BUSTER 2.11.5)
Data quality characteristics
 Overall
Low resolution limit [Å]25.520
High resolution limit [Å]2.210
Number of reflections61903
<I/σ(I)>8.6
Completeness [%]99.0
Redundancy7.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION295100mM MES pH 6 + 25% PEG 4K + 200mM Ammonium Sulfate

222926

PDB entries from 2024-07-24