4X4I
RADIATION DAMAGE TO THE NUCLEOPROTEIN COMPLEX C.Esp1396I: DOSE (DWD) 44.6 MGy
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID29 |
Synchrotron site | ESRF |
Beamline | ID29 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-09-29 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9322 |
Spacegroup name | P 65 |
Unit cell lengths | 104.560, 104.560, 139.470 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 19.011 - 2.800 |
R-factor | 0.2655 |
Rwork | 0.264 |
R-free | 0.29560 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3clc |
RMSD bond length | 0.011 |
RMSD bond angle | 1.338 |
Data reduction software | MOSFLM |
Data scaling software | Aimless (0.2.8) |
Phasing software | PHASER |
Refinement software | PHENIX |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 69.540 | 69.540 | 2.950 |
High resolution limit [Å] | 2.800 | 8.850 | 2.800 |
Rmerge | 0.086 | 0.023 | 2.165 |
Rpim | 0.039 | 0.012 | 0.954 |
Total number of observations | 126715 | 3761 | 18984 |
Number of reflections | 21244 | ||
<I/σ(I)> | 13.1 | 44.8 | 0.9 |
Completeness [%] | 99.9 | 98.2 | 100 |
Redundancy | 6 | 5.4 | 6.1 |
CC(1/2) | 0.997 | 0.993 | 0.226 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 293.15 | MES, MPD, MgCl2 |