Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4TY9

An Ligand-observed Mass Spectrometry-based Approach Integrated into the Fragment Based Lead Discovery Pipeline

Experimental procedure
Experimental methodLAUE
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2013-05-25
DetectorRIGAKU RAXIS HTC
Wavelength(s)1.5415
Spacegroup nameP 21 21 21
Unit cell lengths101.774, 101.643, 251.582
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution42.790 - 2.780
R-factor0.2111
Rwork0.208
R-free0.27349
RMSD bond length0.011
RMSD bond angle1.507
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0049)
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]2.780
Number of reflections66538
<I/σ(I)>12.5
Completeness [%]99.9
Redundancy6.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP289PEG4000, Dithiothreitol, 2-(N-morpholino)ethanesulfonic acid, Glycerin

227111

PDB entries from 2024-11-06

PDB statisticsPDBj update infoContact PDBjnumon