4TLW
CARDS TOXIN, FULL-LENGTH
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-E |
| Synchrotron site | APS |
| Beamline | 24-ID-E |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-04-08 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.97903 |
| Spacegroup name | H 3 |
| Unit cell lengths | 178.431, 178.431, 89.521 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 44.610 - 2.550 |
| R-factor | 0.2 |
| Rwork | 0.198 |
| R-free | 0.24400 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.102 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((PHENIX.REFINE: 1.7.3_928)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.640 |
| High resolution limit [Å] | 2.550 | 2.550 |
| Number of reflections | 34160 | |
| <I/σ(I)> | 20.5 | 2.1 |
| Completeness [%] | 99.1 | 93.2 |
| Redundancy | 4.5 | 4.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 298 | 30% PEG 1000, 0.1 M TRIS-HCL |