4RYF
ClpP1/2 heterocomplex from Listeria monocytogenes
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-07-19 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 1.0 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 97.230, 127.150, 265.500 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 2.900 |
High resolution limit [Å] | 2.800 | 2.800 |
Rmerge | 0.096 | 0.480 |
Number of reflections | 78792 | |
<I/σ(I)> | 14.2 | 3.5 |
Completeness [%] | 96.2 | 98.1 |
Redundancy | 4.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | 0.2 M Sodium-Malonate, 40% MPD, pH 7.0, VAPOR DIFFUSION, SITTING DROP, temperature 293K |