Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4RA0

An engineered Axl 'decoy receptor' effectively silences the Gas6-Axl signaling axis

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL7-1
Synchrotron siteSSRL
BeamlineBL7-1
Temperature [K]100
Detector technologyCCD
Collection date2012-11-19
DetectorADSC QUANTUM 315r
Wavelength(s)1.03317
Spacegroup nameP 32 2 1
Unit cell lengths112.370, 112.370, 361.260
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution38.010 - 3.070
R-factor0.20416
Rwork0.202
R-free0.24255
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2c5d
RMSD bond length0.007
RMSD bond angle1.282
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareMOLREP
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]38.0103.150
High resolution limit [Å]3.0703.070
Rmerge0.1181.000
Number of reflections50592
<I/σ(I)>20.42.11
Completeness [%]99.9100
Redundancy11.97.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.52950.4 M Li2SO4, 0.1 M Tris.HCl(pH 8.5), 5% Glycerol, 2mM NiSO4 , VAPOR DIFFUSION, HANGING DROP, temperature 295K

224201

PDB entries from 2024-08-28