Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X29A |
Synchrotron site | NSLS |
Beamline | X29A |
Temperature [K] | 190 |
Detector technology | CCD |
Collection date | 2008-01-19 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.9793 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 133.516, 133.516, 190.949 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 28.757 - 3.392 |
R-factor | 0.2502 |
Rwork | 0.247 |
R-free | 0.29910 |
Structure solution method | SAD |
RMSD bond length | 0.010 |
RMSD bond angle | 1.463 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SOLVE |
Refinement software | PHENIX ((phenix.refine: 1.9_1692)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 3.520 |
High resolution limit [Å] | 3.389 | 3.389 |
Number of reflections | 26177 | |
<I/σ(I)> | 1.9 | |
Completeness [%] | 94.0 | 59.9 |
Redundancy | 10 | 5.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 277 | 2.4 M ammonium dihydrogen phosphate, 0.1 M Tris, pH 8.5, VAPOR DIFFUSION, SITTING DROP, temperature 277K |