4QML

MST3 in complex with AMP-PNP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]93
Detector technologyCCD
Collection date2012-08-29
DetectorRIGAKU SATURN 944+
Wavelength(s)1.54
Spacegroup nameP 1 21 1
Unit cell lengths47.534, 55.121, 60.879
Unit cell angles90.00, 112.67, 90.00
Refinement procedure
Resolution39.343 - 1.882
Rwork0.190
R-free0.22960
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ckw
RMSD bond length0.008
RMSD bond angle1.160
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX ((phenix.refine: 1.8.4_1496))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0001.910
High resolution limit [Å]1.8801.880
Number of reflections23571
<I/σ(I)>44.15.4
Completeness [%]99.083.1
Redundancy3.53.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.529112.5 mg/mL MST3, 1 mM ANP-PNP, 25 mM TRIS, PH 8.0, 50 MM HEPES pH 7.5, 125 mM SODIUM CHLORIDE, 100 mM MAGNESIUM CHLORIDE, 15% PEG 400, VAPOR DIFFUSION, HANGING DROP, temperature 291K