Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 93 |
| Detector technology | IMAGE PLATE |
| Collection date | 2012-01-09 |
| Detector | RIGAKU RAXIS IV++ |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 65 |
| Unit cell lengths | 59.220, 59.220, 298.500 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 30.000 - 2.130 |
| R-factor | 0.169 |
| Rwork | 0.166 |
| R-free | 0.22200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4GDT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.298 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.250 |
| High resolution limit [Å] | 2.130 | 2.130 |
| Number of reflections | 26285 | |
| <I/σ(I)> | 12.8 | 2.89 |
| Completeness [%] | 79.4 | 53.5 |
| Redundancy | 2.06 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 5.27 | 293 | 0.2 M AMMONIUM IODIDE, 2.2 M AMMONIUM SULFATE, PH 5.27, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 293K |