4P4R
Structural Basis of Chronic Beryllium Disease: Bridging the Gap Between Allergic Hypersensitivity and Autoimmunity
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 273 |
Detector technology | PIXEL |
Collection date | 2013-07-23 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 0.9 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 77.250, 102.440, 120.878 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 78.150 - 3.000 |
R-factor | 0.199 |
Rwork | 0.196 |
R-free | 0.25560 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.300 |
Refinement software | BUSTER (2.10.0) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 90.000 |
High resolution limit [Å] | 3.000 |
Number of reflections | 18043 |
<I/σ(I)> | 4.77 |
Completeness [%] | 91.2 |
Redundancy | 3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.2M NH4tartrate dibasic, 20% PEG-3350 |