4OY4

calcium-free CaMPARI v0.2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.1
Synchrotron siteALS
Beamline8.2.1
Temperature [K]100
Detector technologyCCD
Collection date2012-11-16
DetectorADSC QUANTUM 315r
Wavelength(s)1.0
Spacegroup nameP 43 21 2
Unit cell lengths68.670, 68.670, 172.770
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution53.750 - 2.030
R-factor0.1981
Rwork0.196
R-free0.23519
RMSD bond length0.019
RMSD bond angle2.006
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 Overall
Low resolution limit [Å]57.590
High resolution limit [Å]2.030
Number of reflections27700
<I/σ(I)>13.4
Completeness [%]99.9
Redundancy7.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.5277.150.2 M Ammonium sulfate, 0.1 M HEPES pH 7.5, 25% w/v Polyethylene glycol 3,350, 10 mM EGTA

224931

PDB entries from 2024-09-11