Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4OHD

LEOPARD Syndrome-Associated SHP2/A461T mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 19-BM
Synchrotron siteAPS
Beamline19-BM
Temperature [K]100
Detector technologyCCD
Collection date2011-08-17
DetectorADSC QUANTUM 210r
Wavelength(s)0.97918
Spacegroup nameP 21 21 2
Unit cell lengths54.310, 206.650, 41.881
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution38.814 - 2.700
R-factor0.2059
Rwork0.202
R-free0.27080
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4dgp
RMSD bond length0.009
RMSD bond angle1.186
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwareMOLREP
Refinement softwarePHENIX ((phenix.refine: 1.7.3_928))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.750
High resolution limit [Å]2.7002.700
Rmerge0.1220.309
Number of reflections68055
<I/σ(I)>18.7384.167
Completeness [%]94.974.1
Redundancy5.23.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.329318% PEG3350, 300 mM KF, pH 7.3, VAPOR DIFFUSION, HANGING DROP, temperature 293K

222926

PDB entries from 2024-07-24