4NQT

anti-parallel Fc-hole(T366S/L368A/Y407V) homodimer

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]110
Detector technologyCCD
Collection date2010-09-23
DetectorRAYONIX MX-300
Wavelength(s)0.98
Spacegroup nameC 1 2 1
Unit cell lengths75.468, 44.478, 68.895
Unit cell angles90.00, 106.86, 90.00
Refinement procedure
Resolution37.900 - 2.100
R-factor0.19824
Rwork0.194
R-free0.25284
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1l6x
RMSD bond length0.008
RMSD bond angle1.085
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]38.000
High resolution limit [Å]2.1002.100
Number of reflections12855
Completeness [%]98.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP529125% PEG1500, VAPOR DIFFUSION, SITTING DROP, temperature 291K

221716