4NE1
Human MHF1 MHF2 DNA complexes
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.979 |
Spacegroup name | P 3 |
Unit cell lengths | 252.390, 252.390, 131.360 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 112.590 - 6.499 |
R-factor | 0.2673 |
Rwork | 0.266 |
R-free | 0.29510 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.461 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 112.590 |
High resolution limit [Å] | 6.499 |
Number of reflections | 18329 |
Completeness [%] | 99.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Micro-batch under oil | 300 | 0.1-0.3M ammonium phosphate, Micro-batch under oil, temperature 300K |