4MTS

Ni- and Zn-bound GloA2 at high resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2011-03-16
DetectorADSC QUANTUM 315r
Wavelength(s)0.95370
Spacegroup nameP 65 2 2
Unit cell lengths50.700, 50.700, 327.640
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution19.560 - 1.800
R-factor0.1655
Rwork0.164
R-free0.20060
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4mtr
RMSD bond length0.010
RMSD bond angle0.990
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareBUSTER (2.10.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]19.5601.900
High resolution limit [Å]1.8001.800
Rmerge0.0900.399
Number of reflections24649
<I/σ(I)>25.58.1
Completeness [%]99.999.7
Redundancy19.518.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION7.829331% PEG3350, 0.1 M Tris, 0.2 M magnesium chloride, 10 mM proline, pH 7.8, VAPOR DIFFUSION, temperature 293K