Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-BM |
Synchrotron site | APS |
Beamline | 22-BM |
Detector technology | IMAGE PLATE |
Collection date | 2009-09-18 |
Detector | MAR scanner 300 mm plate |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 88.173, 93.431, 111.737 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 60.000 - 2.500 |
R-factor | 0.223 |
Rwork | 0.221 |
R-free | 0.27700 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.016 |
RMSD bond angle | 1.802 |
Refinement software | REFMAC (5.5.0102) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 60.000 |
High resolution limit [Å] | 2.500 |
Number of reflections | 30619 |
Completeness [%] | 93.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 6.5 | 0.1M BIS-TRIS, 0.05M AMMONIUM ACETATE, PENTAERYTHRITOL ETHOXYLATE(15/4 EO/OH), pH 6.5, EVAPORATION |