4MJR
E. coli sliding clamp in complex with (S)-Carprofen
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
Synchrotron site | Australian Synchrotron |
Beamline | MX1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-08-18 |
Detector | ADSC QUANTUM 210r |
Wavelength(s) | 0.95 |
Spacegroup name | P 1 |
Unit cell lengths | 40.890, 64.190, 71.880 |
Unit cell angles | 74.01, 82.99, 84.03 |
Refinement procedure
Resolution | 21.270 - 1.620 |
R-factor | 0.19122 |
Rwork | 0.189 |
R-free | 0.22529 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4k3s |
RMSD bond length | 0.008 |
RMSD bond angle | 1.336 |
Data reduction software | MOSFLM |
Data scaling software | SCALA (3.3.21) |
Phasing software | MOLREP |
Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 68.769 | 21.919 | 1.710 |
High resolution limit [Å] | 1.620 | 5.120 | 1.620 |
Rmerge | 0.030 | 0.416 | |
Number of reflections | 84110 | ||
<I/σ(I)> | 16.5 | 18.6 | 1.9 |
Completeness [%] | 95.1 | 94.2 | 93.9 |
Redundancy | 3.9 | 3.6 | 3.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 285 | 100mM MES, 100-150mM CaCl2, 25-30%(v/v) PEG400, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 285K |