4MJR
E. coli sliding clamp in complex with (S)-Carprofen
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2011-08-18 |
| Detector | ADSC QUANTUM 210r |
| Wavelength(s) | 0.95 |
| Spacegroup name | P 1 |
| Unit cell lengths | 40.890, 64.190, 71.880 |
| Unit cell angles | 74.01, 82.99, 84.03 |
Refinement procedure
| Resolution | 21.270 - 1.620 |
| R-factor | 0.19122 |
| Rwork | 0.189 |
| R-free | 0.22529 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4k3s |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.336 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA (3.3.21) |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 68.769 | 21.919 | 1.710 |
| High resolution limit [Å] | 1.620 | 5.120 | 1.620 |
| Rmerge | 0.030 | 0.416 | |
| Number of reflections | 84110 | ||
| <I/σ(I)> | 16.5 | 18.6 | 1.9 |
| Completeness [%] | 95.1 | 94.2 | 93.9 |
| Redundancy | 3.9 | 3.6 | 3.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 285 | 100mM MES, 100-150mM CaCl2, 25-30%(v/v) PEG400, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 285K |